Print viewFlame and Flammability Tests

Common International and European fire procedures
Applicable for components (cables)

Standard Part Document title
IEC 332 -1 Test on a single vertical insulated wire or cable
IEC 332 -2 Test on a single vertical insulated wire or cable
IEC 332 -3 Test on bunched wires or cables

Common U.S. fire procedures
Applicable for components (cables)
NEC specifies in Art. 725 and Art. 800 some flame and smoke ratings applicable to coaxial cable products. However, most of these ratings are based on standard flame tests as specified in UL 910, UL 1581 and UL 1666.

UL Standard Document title
UL 910 Test method for fire and smoke characteristics of electrical and optical fiber cables used in air handling spaces
UL 1581 Reference standard for electrical wires, cables, and flexible cords
UL 1666 Standard test for flame propagation height of electrical and optical-fiber cable installed vertically in shafts
UL 1685 Fire test of limited-smoke cables

Applicable for material

UL Standard Document title
UL 94 Tests for flammability of plastic materials for parts in devices and appliances (flammability test description)
UL 1950 Safety of information technology equipment (flammability test description)